Single accessory pathway with multiple insertions? First-in-human 3D visualization using dipole charge density mapping: a case report

5 Halaman

Penulis

, , ,

ISSN

2514-2119 (ONLINE)

Penerbit

Oxford University Press , United Kingdom

Diterbitkan pada

22/08/2023

Bahasa

English

Kata Kunci

, , , ,

Abstrak

Background Accessory pathways (APs) with multiple atrial insertions are often unrecognized and associated with initial catheter ablation (CA) failure. Recently, a novel dipole charge density mapping (DCDM) system was developed that allows mapping of complex arrhythmias based on a single beat. We aim to present the first-in-human report of 3D visualization of a single AP with two atrial insertion sites using high-resolution DCDM. Case summary A 43-year-old man with recurrent symptomatic atrioventricular re-entrant tachycardia and previously failed CA attempts underwent repeated CA using DCDM. Dipole charge density mapping identified two quasi-simultaneous early atrial activation sites at the left lateral and left anterolateral atrial aspects of the mitral annulus, suggesting the presence of a single AP with dual atrial insertion sites. Successful radiofrequency CA was performed at the mid-body of the AP. Discussion The true prevalence of APs with multiple atrial insertion sites may be higher than currently reported. This is the first-in-human report of 3D visualization of a single AP with two atrial insertion sites using high-resolution DCDM. Dipole charge density mapping allows the accurate localization of APs with multiple insertion sites based on a single beat.