Threading the needle: a case report of double-wiring technique and double intracoronary imaging guidance for a multifenestrated iatrogenic coronary artery dissection

5 Halaman

Penulis

, , ,

ISSN

2514-2119 (ONLINE)

Penerbit

Oxford University Press , United Kingdom

Diterbitkan pada

24/04/2023

Bahasa

English

Kata Kunci

, ,

Abstrak

Background Iatrogenic coronary artery dissection (ICAD) may represent a serious complication of percutaneous coronary intervention. Stenting the dissected segment is recommended in large dissections with compromised distal blood flow, although wiring the true lumen is often difficult. Case summary A 64-year-old woman with effort angina was submitted to invasive coronary angiography that revealed a severe stenosis in the distal right coronary artery. A large spiral ICAD occurred after pre-dilatation and guidewire position is lost. We report the treatment of this multifenestrated dissection using combined intracoronary imaging guidance with angiographic co-registered optical coherence tomography and real-time intravascular ultrasound, which were crucial to achieve a successful outcome. Discussion A double-wiring technique with double intracoronary imaging guidance enables a comprehensive depiction of the compromised artery and should be considered in selected cases to guide true lumen wiring and stent implantation.