Re-intervention percutaneous balloon mitral valvuloplasty in a patient with left atrial appendage thrombus: a case report
5 Halaman
Penulis
ISSN
2514-2119 (ONLINE)
Penerbit
Oxford University Press , United Kingdom
Diterbitkan pada
16/09/2022
Bahasa
English
Kata Kunci
Abstrak
Background Percutaneous balloon mitral valvuloplasty (PBMV) using an Accura balloon is an effective method for management of rheumatic mitral stenosis. Case summary Herein, we present a case of a 43-year-old female, who had undergone a previous PBMV, who presented with very severe mitral re-stenosis with Type Ia left atrial (LA) clot, in atrial fibrillation and New York Heart Association functional Class III. We used the modified septal puncture and over-the-wire technique, avoiding inadvertent manipulation of the LA clot for PBMV. The mitral valve was successfully dilated from 0.9 to 1.5 cm2, and the patient had an uneventful post-procedure recovery. Discussion The presence of LA clot and mitral re-stenosis in a previously intervened valve are considered unfavourable characteristics for a PBMV procedure, and patients are usually advised surgical intervention. These patients are also high-risk candidates for surgery due to late presentation with advanced disease and poor functional capacity. Our patient underwent successful re-intervention with PBMV despite having suboptimal characteristics.