The EFFECT OF AIR FLOW RATE VARIATIONS ON THE CHARACTERISTICS OF TWO-PHASE FLOW IN AN AIRLIFT PUMP WITH AN INJECTOR ANGLE OF 15°

11 Halaman

Penulis

, ,

ISSN

2655-903X

Penerbit

Program Studi Teknik Mesin, Universitas Lambung Mangkurat , Indonesia

Diterbitkan pada

23/01/2026

Bahasa

Indonesia

DOI

-

Kata Kunci

, , , ,

Abstrak

Airlift pump is a type of pumping system that utilizes the density difference between air and water to create two-phase flow, commonly applied in closed-loop circulation systems. This study aims to investigate the effect of varying air flow rates on the characteristics of two-phase flow in an airlift pump with a 15° swirl injector. The experimental method was used with air flow variations of 30, 40, 50, and 60 liters per minute (lpm), focusing on parameters such as superficial velocity of liquid and gas, liquid hold-up, gas volumetric quality, and observed flow patterns. The results show that increasing the air flow rate significantly raises the superficial velocities of both liquid and gas. Furthermore, liquid hold-up tends to decrease with higher air flow rates, while gas volumetric quality increases. The observed flow patterns include bubble, slug, and churn flows, each formed depending on the level of injected air flow. Overall, increasing the air flow rate has a significant impact on the hydrodynamic characteristics of the airlift pump system.