Steal syndrome of the hand with a strong palpable radial pulse at the wrist after creation of a basilic-vein-transposition fistula in the arm above the elbow

3 Halaman

Penulis

, ,

ISSN

2772-6878 (ONLINE)

Penerbit

Elsevier , United States

Diterbitkan pada

18/08/2023

Bahasa

English

Kata Kunci

, ,

Abstrak

Steal syndrome is a major complication after creation of an arteriovenous fistula (AVF) and may lead to ischemic symptoms in the hand. A strong palpable radial pulse at the wrist typically excludes the diagnosis of steal syndrome in patients with brachial-artery-based AVF. We present a patient with steal syndrome and a palpable radial pulse after creation of an above-the-elbow AVF using the basilic vein transposition approach. The patient had a brachial artery with high bifurcation and the vein was mistakenly anastomosed to the dominant aberrant ulnar artery. The steal syndrome was treated by proximalization of arterial flow to the proximal brachial artery.