Uncontrolled diabetes mellitus can lead to various chronic complications, including both microvascular and macrovascular issues. The HbA1c test is effective for long-term blood glucose monitoring in individuals with diabetes mellitus, with high HbA1c levels indicating potential complications. Diabetic nephropathy is a common complication of diabetes that can progress to kidney failure, often resulting in damage to the glomeruli. To assess kidney function impairment, creatinine levels are measured. This study aims to determine the correlation between HbA1c and creatinine levels in patients with chronic diabetes mellitus at the Clinical Pathology Laboratory of Bajawa Regional General Hospital. An analytical observational research design with a cross-sectional approach was used, employing purposive sampling of 35 chronic diabetes mellitus patients. Statistical analysis using the chi-square test resulted in a p-value of 0.687, which is greater than the significance level (α) of 0.05. Therefore, it can be concluded that there is no significant relationship between HbA1c levels and creatinine levels in patients with chronic diabetes mellitus.