Risk Factors of Catheter-Related Infection in Patients Undergoing Hemodialysis Using Double Lumen Catheter at Dr. M. Djamil Hospital Padang
8 Halaman
Penulis
ISSN
2598-0580
Penerbit
Universitas Sriwijaya
Diterbitkan pada
07/01/2022
Bahasa
English
Kata Kunci
Abstrak
Background. Chronic kidney disease (CKD) is a terminal disease requiring hemodialysis. Hemodialysis requires vascular access using a double lumen catheter (DLC). However, the use of DLC may increase complications, mainly infections, either at the exit site or in the bloodstream. This study aims to seek risk factors contributing to the incidence of central catheter-related infections in CKD patients with DLC undergoing HD at Dr. M. Djamil Hospital, Padang. Methods. This study is a prospective study on patients undergoing HD at Dr. M. Djamil Hospital, Padang. This study used a consecutive sampling technique. Data were analyzed using SPSS version 25.0. Results. This study involved 40 CKD patients undergoing HD. The majority of the samples had bloodstream infections (67.5%). Clinical manifestations of purulent secretion, duration of catheter use, and hypoalbuminemia had significant differences in the incidence of DLC infection based on bloodstream infection and exit site infection (p<0.05). The most common bacteria found was Pseudomonas aeruginosa (22.5%), which was sensitive to ceftazidime, cefepime, meropenem, amikacin, gentamicin, and ciprofloxacin. Conclusion. Factors contributing to the incidence of DLC-related infections at Dr. M. Djamil Hospital are the duration of catheter use and hypoalbuminemia. Pseudomonas aeruginosa is the most common cause of DLC-related infections.